EAGLE SERIES LED FAULT CODE INDICATIONS
All Eagle Series Chargers are designed to constantly monitor the charger circuitry and alert the user to possible charger and/or battery problems.
![]() |
NO BATTERY DETECTED | This indication occurs whenever the charger circuitry cannot detect a battery. The charger circuitry will not allow charge current to flow under this condition. |
![]() |
FORMING STAGE TIMEOUT SHUTDOWN |
This indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first three hours of charging. This indicates a possible battery problem and the charge cycle will be terminated at this point. |
![]() |
OVERALL TIMER SHUTDOWN |
This indication occurs if the charger has not completed the charge cycle within the allowable factory set time period. This indicates a possible battery problem and the charge cycle has been terminated at this point. |
![]() |
INTERNAL OVERTEMP SHUTDOWN | This indication occurs if the charger circuitry has detected operating temperature inside the charger enclosure that are above factory specified levels. This could indicate a possible charger problem and the charge cycle will be terminated at this point. |
![]() |
PROTECTION CIRCUIT ALERT |
This indication occurs if the charger circuitry has detected a possible malfunction in the charge circuit. |